3/8″ insulated copper pipe for air conditioners ISOCLIMA 25m
€122.34 Incl. VAT
ISOCLIMA ISOPOLAR 3/8″ (9.52 mm) insulated copper pipe for air conditioners and heat pumps 25 m. Designed for refrigerant line installations in split, multi-split and VRV systems and suitable for R32, R410A and R407C refrigerants. Flexible closed-cell insulation helps prevent surface condensation and provides reliable thermal protection for HVAC installations.
- Fast delivery across Europe (5-10 business days)
- 30-day returns
- No customs duties within the EU
- Secure payments
ISOCLIMA ISOPOLAR 3/8″ Insulated Copper Pipe 25m
ISOPOLAR 3/8″ insulated copper pipe for air conditioners and heat pumps provides a flexible solution for professional refrigerant line installations. The 25 m pipe is designed for split, multi-split and VRV air conditioning systems and is suitable for R32, R410A and R407C refrigerants.
The copper tube has a 9.52 mm outside diameter and 0.80 mm wall thickness, providing reliable performance under the operating pressures required for HVAC refrigerant lines. It is protected by 7 mm closed-cell insulation, resulting in a total insulated diameter of 25.52 mm.
The flexible insulation provides high resistance to water vapour diffusion, helping prevent condensation on the copper pipe surface when refrigerant temperatures are below ambient temperature. Its insulated construction also provides thermal protection while facilitating routing and installation of refrigerant pipework.
KEY FEATURES
- Insulated copper pipe: 3/8″ (9.52 mm)
- Bare copper pipe dimensions: 9.52 × 0.80 mm
- Length: 25 m
- Insulation thickness: 7 mm
- Total diameter with insulation: 25.52 mm
- Suitable for R32, R410A and R407C refrigerants
- Nominal working pressure: 9.43 MPa
- Nominal burst pressure: 37.71 MPa
- Operating temperature range: −80 °C to +98 °C
- Flexible closed-cell insulation
- High resistance to water vapour diffusion
- Helps prevent surface condensation
APPLICATIONS
Insulated freon pipe suitable for air conditioners, heat pumps, split, multi-split and VRV systems requiring insulated copper refrigerant piping. Designed for reliable refrigerant line installations using R32, R410A and R407C refrigerants.
ISOCLIMA BIPOLAR Technical Data Sheet
| Weight | 4.7 kg |
|---|---|
| Dimensions | 680 × 680 × 90 mm |
| Product type | Refrigerant pipes |
| Product diameter Ø (mm) | 9.52 |
| Diameter (inch) | 3/8″ |
| Length (m) | 25 |
| Wall thickness (mm) | 0.8 |
| Insulation thickness (mm) | 7 |
| Temperature range (°C) | -80 / +98 |
| Refrigerants | R32, R407/C, R410/A |
| Package Weight (kg) | 4.7 |
| Color | White |
| Material | Copper, Polyethylene |
| Country of origin | Italy |
| Brand | ISOCLIMA |
| Manufacturer | ISOCLIMA S.p.A. |
Related products
5/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
Insulated Copper Pipe 5/8″ (15.87 mm) for Air Conditioners & Heat Pumps 25 m. Engineered for refrigerant piping in split, multi-split, and VRV air conditioning systems. Its flexible copper tube with durable thermal insulation offers excellent resistance to water vapour diffusion, helping reduce condensation, simplify installation, and ensure reliable long-term performance.
5/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 50m
ISOCLIMA ISOPOLAR 5/8″ (15.87 mm) insulated copper pipe for air conditioners and heat pumps, supplied in a 50 m. Designed for refrigerant line installations in split and VRV systems and suitable for R32, R410A and R407C refrigerants. Flexible thermal insulation with high resistance to water vapour diffusion helps prevent surface condensation while supporting reliable HVAC installation.
7/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
ISOCLIMA ISOPOLAR 7/8″ (22.22 mm) insulated copper pipe for air conditioners and heat pumps 25 m. Designed for refrigerant line installations in split and VRV systems and suitable for R32, R410A and R407C refrigerants. Flexible insulation with high resistance to water vapour diffusion helps prevent surface condensation
ISOCLIMA 1/4″ – 1/2” twin insulated copper pipe for air conditioners 20 m
ISOCLIMA BIPOLAR 1/4″–1/2″ (6.35–12.70 mm) twin insulated copper pipe for air conditioners and heat pumps 20 m. Suitable for R32, R410A and R407C refrigerants, this paired copper pipe provides flexible and reliable refrigerant line installation for split air conditioning systems while helping protect pipework against surface condensation.
ISOCLIMA twin insulated copper pipe for air conditioners 1/2” – 3/4” (12.70-19.05 mm) 20 m
ISOCLIMA BIPOLAR 1/2″–3/4″ (12.70–19.05 mm) twin insulated copper pipe for air conditioners and heat pumps, supplied in a 20 m coil. Designed for refrigerant line installations in split systems and suitable for R32, R410A and R407C refrigerants. Flexible 10 mm closed-cell insulation helps prevent surface condensation and provides reliable thermal and mechanical protection.
ISOCLIMA Twin Insulated Copper Pipe for Air Conditioners 1/4″ – 3/8″ × 20 m
ISOCLIMA BIPOLAR 1/4″–3/8″ (6.35–9.52 mm) twin insulated copper pipe for air conditioners and heat pumps. Designed for refrigerant line installations in split systems and suitable for R32, R410A and R407C refrigerants. Flexible closed-cell insulation provides high resistance to water vapour diffusion, helping prevent condensation on refrigerant pipework. 20m roll.
ISOCLIMA twin insulated copper pipe for air conditioners 1/4″ – 5/8” × 20 m
ISOCLIMA BIPOLAR 1/4″–5/8″ (6.35–15.87 mm) twin insulated copper pipe for air conditioners and heat pumps 20 m. Designed for refrigerant line installations in split systems and compatible with R32, R410A and R407C refrigerants. Flexible closed-cell insulation provides high resistance to water vapour diffusion, helping prevent condensation on refrigerant pipework.
ISOCLIMA twin insulated copper pipe for air conditioners 3/8″ – 5/8” x 20 m
ISOCLIMA BIPOLAR 3/8″–5/8″ (9.52–15.87 mm) twin insulated copper pipe combines two refrigerant lines for split air conditioning and heat pump installations. Compatible with R32, R410A and R407C refrigerants, its flexible closed-cell insulation provides high resistance to water vapour diffusion, helping reduce condensation on refrigerant pipework. 20m