ISOCLIMA twin insulated copper pipe for air conditioners 3/8″ – 3/4” (9.52-19.05 mm) x 20 m
€365.25 Incl. VAT
ISOCLIMA BIPOLAR 3/8″–3/4″ (9.52–19.05 mm) twin insulated copper pipe for air conditioners and heat pumps 20 m. Designed for refrigerant line installations in split systems and suitable for R32, R410A and R407C refrigerants. Flexible closed-cell insulation helps prevent surface condensation and provides reliable thermal and mechanical protection.
- Fast delivery across Europe (5-10 business days)
- 30-day returns
- No customs duties within the EU
- Secure payments
ISOCLIMA BIPOLAR Twin Insulated Copper Pipe 3/8″–3/4″ (9.52–19.05 mm)
BIPOLAR 3/8″–3/4″ twin insulated copper pipe combines 9.52 mm and 19.05 mm pre-insulated copper pipes for professional refrigerant line installations in air conditioning and heat pump systems. Supplied in a 20 m, it is suitable for split systems using R32, R410A and R407C refrigerants.
The freon pipes feature individual low-density closed-cell polyethylene foam insulation, with 7 mm insulation on the 3/8″ pipe and 10 mm on the 3/4″ pipe. High resistance to water vapour diffusion helps prevent condensation from forming on the pipe surface when refrigerant temperatures are below the surrounding air temperature.
The insulation is protected by an extruded, embossed white PE-LD outer film, providing additional mechanical protection during handling and installation. The insulation material is non-toxic, odourless and CFC-free, while its flexibility facilitates routing and installation of refrigerant pipework.
KEY FEATURES
- Twin insulated copper pipe: 3/8″ + 3/4″ (9.52 + 19.05 mm)
- Copper pipe dimensions: 9.52 × 0.8 mm + 19.05 × 1.0 mm
- Length: 20 m
- Insulation thickness: 7 mm + 10 mm
- Suitable for R32, R410A and R407C refrigerants
- Nominal working pressure: 9.43 / 5.89 MPa
- Nominal burst pressure: 37.71 / 23.55 MPa
- Operating temperature range: −80 °C to +98 °C
- Flexible closed-cell polyethylene insulation
- High resistance to water vapour diffusion
- Helps prevent surface condensation
- Embossed white PE-LD protective outer film
- Non-toxic, odourless and CFC-free insulation
- Supplied in a protective clear-film wrapped coil
APPLICATIONS
Suitable for air conditioners, heat pumps and split systems requiring paired insulated copper refrigerant lines. Designed for reliable refrigerant transport with R32, R410A and R407C while providing thermal insulation and protection against surface condensation.
ISOCLIMA BIPOLAR Technical Data Sheet
| Weight | 13.9 kg |
|---|---|
| Dimensions | 810 × 810 × 160 mm |
| Product type | Refrigerant pipes |
| Product diameter Ø (mm) | 19.05, 9.52 |
| Length (m) | 20 |
| Insulation thickness (mm) | 10, 7 |
| Wall thickness (mm) | 0.8, 1 |
| Refrigerants | R32, R407/C, R410/A |
| Package Weight (kg) | 13.9 |
| Color | White |
| Material | Copper, Polyethylene |
| Brand | ISOCLIMA |
| Country of origin | Italy |
| Manufacturer Code | BIPOLAR 3/8″ – 3/4” |
| Manufacturer | ISOCLIMA S.p.A. |
Related products
1/2″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
ISOCLIMA ISOPOLAR 1/2″ (12.70 mm) insulated copper pipe for air conditioners and heat pumps 25 m. Suitable for R32, R410A and R407C refrigerants in split and VRV systems. Flexible pre-insulated copper tubing supports reliable refrigerant piping while its high resistance to water vapour diffusion helps reduce surface condensation.
1/4” Insulated Copper Pipe for Air Conditioners ISOCLIMA 50m
ISOCLIMA ISOPOLAR insulated copper pipe 1/4″ (6.35 mm) for air conditioners and heat pumps 50 m. Designed for refrigerant line installations in split, multi-split and VRV systems and suitable for R32, R410A and R407C refrigerants. Flexible thermal insulation with high resistance to water vapour diffusion helps prevent surface condensation and supports reliable HVAC installation.
3/4″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
ISOCLIMA ISOPOLAR 3/4″ (19.05 mm) insulated copper pipe for air conditioners and heat pumps. Suitable for R32, R410A and R407C refrigerants in split and VRV systems. Flexible pre-insulated copper tubing provides reliable refrigerant piping while high resistance to water vapour diffusion helps prevent surface condensation. 25m roll.
3/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 50m
5/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
Insulated Copper Pipe 5/8″ (15.87 mm) for Air Conditioners & Heat Pumps 25 m. Engineered for refrigerant piping in split, multi-split, and VRV air conditioning systems. Its flexible copper tube with durable thermal insulation offers excellent resistance to water vapour diffusion, helping reduce condensation, simplify installation, and ensure reliable long-term performance.
5/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 50m
ISOCLIMA ISOPOLAR 5/8″ (15.87 mm) insulated copper pipe for air conditioners and heat pumps, supplied in a 50 m. Designed for refrigerant line installations in split and VRV systems and suitable for R32, R410A and R407C refrigerants. Flexible thermal insulation with high resistance to water vapour diffusion helps prevent surface condensation while supporting reliable HVAC installation.
7/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
ISOCLIMA ISOPOLAR 7/8″ (22.22 mm) insulated copper pipe for air conditioners and heat pumps 25 m. Designed for refrigerant line installations in split and VRV systems and suitable for R32, R410A and R407C refrigerants. Flexible insulation with high resistance to water vapour diffusion helps prevent surface condensation
ISOCLIMA twin insulated copper pipe for air conditioners 3/8″ – 5/8” x 20 m
ISOCLIMA BIPOLAR 3/8″–5/8″ (9.52–15.87 mm) twin insulated copper pipe combines two refrigerant lines for split air conditioning and heat pump installations. Compatible with R32, R410A and R407C refrigerants, its flexible closed-cell insulation provides high resistance to water vapour diffusion, helping reduce condensation on refrigerant pipework. 20m