1/2″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 50m
€365.75 Incl. VAT
ISOCLIMA ISOPOLAR 1/2″ (12.70 mm) insulated copper pipe for air conditioners and heat pumps 50 m. Designed for refrigerant line installations in split and VRV systems and suitable for R32, R410A and R407C refrigerants. Flexible insulation with high resistance to water vapour diffusion helps prevent surface condensation
- Fast delivery across Europe (5-10 business days)
- 30-day returns
- No customs duties within the EU
- Secure payments
ISOCLIMA ISOPOLAR 1/2″ Insulated Copper Pipe for Air Conditioners 50 m
1/2″ copper pipe with insulation is designed for air conditioners, heat pumps and professional refrigerant line installations. This 50 m copper pipe with insulation is suitable for R32, R410A and R407C refrigerants and is designed for split and VRV systems.
The pre-insulated copper tubing has a 12.70 mm outside diameter and 0.8 mm copper wall thickness. The copper tubing complies with EN 12735-1:2020 for round copper tubes used in air-conditioning and refrigeration systems and is manufactured from CU-DHP copper alloy with a minimum copper content of 99.9%.
The refrigerant copper pipe is protected by 10 mm low-density closed-cell polyethylene foam insulation. High resistance to water vapour diffusion helps prevent condensation on the pipe surface when refrigerant temperatures are below ambient temperature. An embossed white PE-LD outer film provides additional mechanical protection, while the insulation is non-toxic, odourless and CFC-free.
KEY FEATURES
- Insulated copper pipe for air conditioners and heat pumps
- Pipe size: 1/2″ (12.70 mm)
- Length: 50 m
- Wall thickness: 0.8 mm
- Insulation thickness: 10 mm
- Total diameter with insulation: 32.7 mm
- Suitable for R32, R410A and R407C refrigerants
- Nominal working pressure: 7.07 MPa
- Nominal burst pressure: 28.27 MPa
- Operating temperature range: −80 °C to +98 °C
- High resistance to water vapour diffusion
- Helps prevent surface condensation
- Fire reaction class: BL-s1,d0
- Embossed white PE-LD protective outer film
- Non-toxic, odourless and CFC-free insulation
APPLICATIONS
Suitable for air conditioners, heat pumps, split and VRV systems requiring insulated copper refrigerant piping. This single copper pipe is designed for transporting R32, R410A and R407C refrigerants in air conditioning, refrigeration and HVAC installations.
ISOCLIMA ISOPOLAR Technical Data Sheet
| Weight | 15.1 kg |
|---|---|
| Dimensions | 830 × 830 × 150 mm |
| Product type | Refrigerant pipes |
| Diameter (inch) | 1/2″ |
| Product diameter Ø (mm) | 12.7 |
| Length (m) | 50 |
| Wall thickness (mm) | 0.8 |
| Insulation thickness (mm) | 10 |
| Refrigerants | R32, R407/C, R410/A |
| Package Weight (kg) | 15.1 |
| Color | White |
| Material | Copper, Polyethylene |
| Country of origin | Italy |
| Brand | ISOCLIMA |
| Manufacturer | ISOCLIMA S.p.A. |
| Manufacturer Code | ISOPOLAR 1/2″ 50m |
Related products
1/2″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
ISOCLIMA ISOPOLAR 1/2″ (12.70 mm) insulated copper pipe for air conditioners and heat pumps 25 m. Suitable for R32, R410A and R407C refrigerants in split and VRV systems. Flexible pre-insulated copper tubing supports reliable refrigerant piping while its high resistance to water vapour diffusion helps reduce surface condensation.
1/4” Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
Insulated Copper Pipe 1/4″ (6.35 mm) for Air Conditioners & Heat Pumps 25 m. Suitable for refrigerant line installations in split and VRV air conditioning systems, this flexible insulated copper pipe provides dependable thermal protection and excellent resistance to moisture diffusion. It helps prevent surface condensation while enabling quick installation and reliable long-term performance.
1/4” Insulated Copper Pipe for Air Conditioners ISOCLIMA 50m
ISOCLIMA ISOPOLAR insulated copper pipe 1/4″ (6.35 mm) for air conditioners and heat pumps 50 m. Designed for refrigerant line installations in split, multi-split and VRV systems and suitable for R32, R410A and R407C refrigerants. Flexible thermal insulation with high resistance to water vapour diffusion helps prevent surface condensation and supports reliable HVAC installation.
5/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 25m
ISOCLIMA ISOPOLAR 5/8″ (15.88 mm) insulated single copper pipe for air conditioners and heat pumps 25 m. Suitable for R32, R410A and R407C refrigerants in split and VRV systems. Flexible pre-insulated copper tubing provides reliable refrigerant piping, while high resistance to water vapour diffusion helps prevent surface condensation.
5/8″ Insulated Copper Pipe for Air Conditioners ISOCLIMA 50m
ISOCLIMA ISOPOLAR 5/8″ (15.87 mm) single insulated copper pipe for air conditioners and heat pumps, supplied in a 50 m. Designed for refrigerant line installations in split and VRV systems and suitable for R32, R410A and R407C refrigerants. Flexible thermal insulation with high resistance to water vapour diffusion helps prevent surface condensation while supporting reliable HVAC installation.
ISOCLIMA 1/4″ – 3/8″ Twin Insulated Copper Pipe for Air Conditioners 20 m
ISOCLIMA BIPOLAR 1/4″–3/8″ (6.35–9.52 mm) twin insulated copper pipe for air conditioners and heat pumps. Designed for refrigerant line installations in split systems and suitable for R32, R410A and R407C refrigerants. Flexible closed-cell insulation provides high resistance to water vapour diffusion, helping prevent condensation on refrigerant pipework. 20m roll.
ISOCLIMA 3/8″ – 3/4” Twin Insulated Copper Pipe for Air Conditioners 20 m
ISOCLIMA BIPOLAR 3/8″–3/4″ (9.52–19.05 mm) twin insulated copper pipe for air conditioners and heat pumps 20 m. Designed for refrigerant line installations in split systems and suitable for R32, R410A and R407C refrigerants. Flexible closed-cell insulation helps prevent surface condensation and provides reliable thermal and mechanical protection.
ISOCLIMA 3/8″ – 5/8” Twin Insulated Copper Pipe for Air Conditioners 20 m
ISOCLIMA BIPOLAR 3/8″–5/8″ (9.52–15.87 mm) twin insulated copper pipe combines two refrigerant lines for split air conditioning and heat pump installations. Compatible with R32, R410A and R407C refrigerants, its flexible closed-cell insulation provides high resistance to water vapour diffusion, helping reduce condensation on refrigerant pipework. 20m























